Installing and setting in motion of water purification systems

1 - at first cut off cold water faucet of urban network and wrap tape around steel linkages(A-10) system after that bring into connect entrance of cold water then attach the upper entrance of first stage s filter from channel hose to steel faucet .

سه راهی استیل

2 - bring into connect ball valve to exit ¼ (A-11)that it was placed on steel fitting three way(A-10) joint.entrance water to water purification system will connect and cut by valve(A-11) . b

شیر ورودی

3 - affix faucet(A-3) on sink

شیر فلکه ای

4 - after that cut hose sufficiently and attach from blue valve to entrance RO on housing of first stage .

5 - divert flow restrictor (A-16) that had been cennected to system s body by hose to sewage route .

کپسول فاضلاب

6 - bring connect ball valves for tank(A-14) into tank .

شیر تانک

7 - open the bousing membrane cap and put membrane into housing

ممبرین

8 - purified Water in the first fifth stage enter to supply tank And by Tap(hose) after passing through stages five
and six, move to exit faucet(A-3) .thus Should be cut some of the existing tap ,
And tap connected to " Three way" before the 5satge at to "ball valves for tank(A-14)" ,
And tap connected to The output of the sixth stage at to faucet(A-3)b

 

9 - bring connect ending of sixth stage into tap .

10 - if equipped mix valve should be close gauge direction completely

11 - if equipped back wash valve you can open 1mill it .

Now system is setting in motion and for washing filters should be b

1 - plug in system

2 - set open blue valve(A-11)b

3 - close ball valve for tank

4 - keep open the purified water for 10min for washing filters

5 - open the faucet(A-3) for filling tank with water

6 - Close the faucet(A-3), until the tank is filled with water

Remarks:should be watertight carefully and don’t allow water to get in or out by tape

 

عملکرد دستگاه تصفیه آب

Remarks: when the system don’t work at first pay attention according instructions whereas it doesn’t solve contact with company or representation or agent s office .

The system work intermittently and entrance controlling faucet connect and cut constantly

it isnt enough pressure of entrance water.you should be change first filter or affix approprate pump on entrance water

dont cut exit sewage after switch off system

hard particles are palced in course of control faucet that should be clean

water pump is working but it doesn’t make suffiecnt pressure

maybe the setting of pump pressure are changed so fix button set aside for pressure

the system have stopped working completely

A:electricity was cut off by high pressure or low pressure

B: Pump or transformator have stopped working

 the entrance water pressure is normal but purified water or sewage doesn’t exit

should be change carbon active filter

the entrance water pressure is normal but purified water exit very low or connect and cut

should be change membrane filter

increasing the quantity of exit purified water and salts

change membrane because membrane s vents become enlarged

filling tank but exit water is low

air pressure from the bottom is less 8psi or 10psi you can increase air pressure till8psi or changing tank

pressurized tank is working normally but water doesn’t exit

 

carbon active filter for fifth stage got clogged and should be change it

pump was leaking

watertighting s washer of the head of pump should be change

 

The method of changing filters :

1.plug out system .

2.keep colsing ball valve for tank .

3.keep open gate valve(A-13) .

4.close gate valve (A-13) .

5.be patient one moment till get 5psi.

6.open housing by wrench .

7.then replace new filter inside housing .

8.open entrance faucet(A-13) and plug in .